Rosemount Model 751 Remote Signal Indicator
Example Model Number: 751 A M1 NA BC
Input Signal
A --- 4 - 20 mA dc
B --- 10 - 50 mA dc (Not Available with LCD Meter)
C --- 40 - 200 mV dc (Not Availabel with LCD Meter)
Meter
M1 --- Linear Meter, 0 - 100% Scale
M2 --- Square Root Analog Meter, 0 - 100% Flow
M3 --- Special Scaling Analog Meter (specify range)
M6 --- Square Root Analog Meter, 0 - 10 sq. rt.
M4 --- Linear LCD Meter, 0 - 100% Scale
M7 --- Special Scale LCD Meter (specify range, mode and engineering units)
M8 --- Square Root LCD Meter, 0 - 100% Flow
M9 --- Square Root LCD Meter, 0 - 10 sq. rt.
Options
NA --- No Approval Required
E5 --- Factory Mutual (FM) Explosion-Proof Approval
E6 --- Canadian Standards Association (CSA) Explosion-Proof Approval
E7 --- Standards Association or Australia (SAA) Explosion-Proof Certification
E8 --- Centro Elettrotecnico Sperimentale Italiano (CESI) Explosion-Proof Certification
I5 --- Factory Mutual (FM) Intrinsic Safety and Non-incendive Approval
I6 --- Canadian Standards Association (CSA) Intrinsic Safety Approval
I7 --- Standards Association or Australia (SAA) Intrinsic Safety Certification
I8 --- Centro Elettrotecnico Sperimentale Italiano (CESI) Intrinsic Safety Certification
N1 --- British Approvals Service for Electrical Equipment in Flammable Atmospheres (BASEEFA) Non-incendive Certification
C6 --- E6 and I6 Combination
Accessories
B --- Mounting Bracket for Flat Surface or 2 - inch Pipe
C --- Stainless Steel Reducer 3/4 to 1/2 - inch for Conduit Connection